You can tell if youre using fire-rated plywood by looking at it. ceiling (suspended), embossed tin, 2" x 12" F/D @ 16' o.c., span 18'-20', live load 40lbs, 1/2" GWB. Add to basket. The board's excellent fire resistance rating makes it ideal for lining walls and ceilings in commercial spaces like offices and shopping centres, as well as in low rise housing and new build garages. CenturyPlys fire- retardant plywood, delays the spread of fire, giving you the much-needed time to rescue yourself and your loved ones. ASTM E-2768- A newer standard in fire ratings, this test is usually called a 30-minute version of the ASTM E84 test. Don't miss the latest insights, news and product offerings from USG. Giving customers critical time to act, save lives, and call for emergency services. 35' span, w 2" x 4" joists @ 24o.c. 4" x 12" beams @ 4' o.c., 1-1/8" T&G plywood, span 24', live load 20lbs, 2" x 4" or 2 x 6 trusses @24" o.c., 5/8" CDX plywood, live load 60 lbs, span 60', 2" x 12"/2" x 10" @ 12" o.c., 1/2" plywood, 12" x 36" GLB, 80' span @20'o.c., roof load 20 lbs, 8-3/4" x 48" o.c. J B Kind STP Flush Plywood Kigog Fire Door - 1/2 Hour Fire Rated - Wired Fire Glass. span 35' load 20lbs, 6" x 36" Glu-lam support beam 35' o.c. Your Do You Need to Hire a Framing Contractor? All rights reserved. "\\\\7503\\\\\\\\^JO]VT5[02\\\\\\\\0j01\\\\\\\\_QXF7D01\\\\\\\\14\\\\0q\\\\D" +
For fire-retardant wood to be substituted for a noncombustible material, it is required to have a Class A rating. You have been logged out due to inactivity. The pressure is applied to help the chemicals infuse the wood fully and evenly for a length of time that is appropriate to the type, thickness, and amount of wood being treated. w/1-1/8" T&G plywood floor, 1-1/2" gypcrete, span 16', live load 60lbs, 5-1/2" X 11-1/2"joists @ 5'9"O.C., span 15', live load 60lbs, 3" x 8" T&G Flooring, 3" x 11-1/2" F/D joists @16" O.C., Span 15', live load 60lbs, 1 layer 2" x 8" T&G, 1 layer wood flooring, 3" x 8" joists @14.5 o.c., span 24', live load 40lbs, 2 layers 3/4" wood, 2" x 8"joists @16"o.c., span 6'6", live load 80lbs, 3/4" t&g plywood/OSB, 3/4" gypcrete, 2" x 4" web trusses @24" o.c. Please refer to the technical user guideline "Medite Premier FR 30 minute Partition Wall" and "Medite Premier FR 60 minute . FlamePRO Fire-Retardant-Treated Wood (FRTW) has been tested for fire performance by several independent laboratories and meets model code requirements for a Class A/Class 1 fire retardant. {
"A7I00\\\\\\\\BMCTQAGKp`sx!umu~txwO6w/}u-f7m! Thus it is best prepared to fight against self disintegration due to fire, containing the spread of fire and smoke generation.This In turn helps rescue operations and gives customer critical time to act, save own and others lives, call for fire brigade, ambulance etc. Showing 1 - 36 of 297 products. All the other properties of the plywood are retained. Our product is ICC Listed and UL Classified and can be found in the ICC Listing Directory and UL Product iQ, and below. Fire-retardant wood products like fire-rated plywood are widely used in construction projects to help increase safety and minimize damage in the event of a fire. "url": "https://www.firefree.com",
Wood must contain these labels to meet International Building Code standards. This paint is especially suitable for use on insulation board, MDF board, plasterboard, wood . Firewall Technology increases the duration it takes for fire to multiple across itself or to other neighbouring products. - In critical situations, like a fire accident, the human mind usually starts panicking, and thus it becomes difficult to make practical decisions. Doors supplied may visually differ to images used based on supply issues with face veneers. The work was completed in four working days and at a greatly reduced cost and less disruption. Wood is also prone to igniting earlier than plastic, which is why most people tend to prefer plastic when it comes to areas that are prone to heat. To be officially considered fire-retardant, treated wood must have been infused with the chemicals in a pressure process and have a listed Flame Spread Index of 25 or less in testing. Those will give you a good idea of what to expect. w/3/4" T&G plywood, 2-1/2" concrete, live load 60lbs, 2" x 4" web trusses @24" o.c. Burning droplets/particles are measured for Reaction to Fire classes A2 to E. E-rated products receive a d2 flaming droplet classification. sheets and other manuals, Wildfire System
The first way to do it is to use a pressure treating system to infuse fire-proofing chemicals into the wood. New posts Search forums. The gained insulating char protects the elements composing the substrate from fire. We stock a wide range of Fire Retardant Panels, which include MDF, Chipboard, Plywood and OSB. While treated lumber does have its perks in terms of durability, the truth is that it is not meant to be fire-resistant. We recommend that suitability of a Euroclass rated panel within the design is based upon 3rd party assessment or independent testing specific to the project in question. w/ 4layers of wood flooring, total 2-1/2", span 23'-24', live load 40lbs, 3" x 14" joists @ 16" o.c., w/3/4" T&G plywood, 1-1/4" gypcrete, span 16', live load 40lbs, 7-1/4" x 13" joists @50" o.c., w/ 3" wood planking, 3" concrete supported on double 6" x 15" beams, span 17', live load 60lbs, 8" x 12" F/D joists @ 8' o.c., w/ 3" x 6" T&G wood floor, span 25', live load 40lbs, 2" X 4" web trusses @ 19'-2" o.c., w/3/4" T&G plywood, span engineered, live load 60lbs, 3" x 10" F/D @ 16" o.c., w/multiple layers of wood @ 2-1/4" thickness, span 9', live load 60lbs, 2" x 14" joists @ 16" o.c., w/ 2" x 4" diagonal bridging @ 8" o.c., span 25', live load 40lbs1 layer 1" diagonal wood sheathing, 2" x 14" F/D joists @ 16" o.c., span 11'-6", live load 40lbs, 1 layer 1" diagonal wood sheathing, 11-7/8 TJI's @ 16" o.c., live load 40 lbs, 3/4" T&G plywood, 7" x 13" @ 48" o.c., live load 40lbs, Beams Double 7-1/2" x 19", span 19'-3", 3" T&G wood plank, 2-1/4" x 13-1/2" wood@16" o.c., span 16', live load 60lbs, 2" wood decking, 2" x 11-1/2" f/d oak @12" o.c., span 18', live load 60lbs, 1" hardwood oak planking, 8" diameter beams @48" o.c. So we appreciate sometimes this lead time can be a problem.
Plywood with Firewall technology is non-hygroscopic in nature. The most common differences include one and two-hour rated plywood. If the wood is designed for exterior use, it will also contain a required statement for wood products that will be exposed to wet, damp, or other weather conditions. The revolutionary Firewall Technology from the house of CenturyPly, the most reliable fire retardant plywood manufacturer, enables a select range of CenturyPly plywood to be the best fire-fighting plywood available in India. w/1-1/8" T&G plywood, 1-1/2" gypcrete, span 7' to 10', live load 60lbs, 11-7/8" TJ'I's @ 16" o.c. Fire-rated plywood is a type of plywood that has been specially treated with chemicals that create a physical barrier to the spread of flames. The product is available in a range of thicknesses with either a Euroclass B or C fore rating in accordance with European Standards. 1 layer 5/8" type X gwb, 2" x 12" @24" o.c., 1/2" GWB, 1/2"plywood, 1 layer 5/8" GWB, 2" x 6" @24" o.c., 1/2" GWB, 1/2" RC channel, 1 layer 5/8" GWB, 2" x 10" Rafters @ 12" o.c., 1/2" plywood decking, 1 layer 5/8" type "X" gwb, 12" x 36" glulam beam., roof load 20lbs, 2" x 4" (1-1/2" wide) wood web trusses @24" o.c.,5/8" T&G plywood, R-30 fiberglass insulation, 1-1/2" x 25 gauge hat channel w 1 layer 1/2" sheet rock, 2" x 4" (1-1/2" wide) wood web trusses @ 24" o.c., 3/4" T&G OSB, 1 layer of 5/8" type "X" gwb, 2" x6" (1-1/2" wide) wood web trusses @ 24" o.c., 5/8" T&G plywood, 1 layer of 5/8" type "X" gwb, 2" X 4" (1-1/2" wide) wood web trusses @ 24" o.c., 19/32" OSB roof decking, 1-1/2" RC channel, 1 layer 5/8" type "X" gwb, 2" x 4" studs @16" o.c., w/ 1/2" GWB. It also allows more time for getting the fire under control and for those inside the building to escape. Fire-retardant Plywood substantially reduces this emission, thus preventing you from suffocation. We'll send you a link that lets you create a new password. "@type": "ContactPoint",
w/ 2" x 4" @24"o.c. Firefree 88 Assemblies by Building Material with 1 & 2 Hour Fire Ratings . w/3/4" T&G OSB w/live load 40lbs: WFC30: Wood: Floor / Ceiling: . Writing is her life, and it's what she does best. "@type": "Organization",
8 Commercial Blvd, Suite E
It combines flame-spread and burn-through resistance to give your customers peace of mind. For Wood Products, call: 1-800-284-5347; For Gypsum Products, call: 1-800-225-6119; Fire Safety Important Fire Safety Information regarding: PDF: Georgia-Pacific Fire Rated Products (65KB/2pgs) PDF: Fire Rated Building Assemblies and Components of Fire Rated Assemblies (19KB/1pgs) PDF: HRA Finger-Jointed Lumber Products (79KB/2pgs) PDF: Georgia-Pacific Gypsum FireDefender Firedoor Components . This makes this range of CenturyPly the first and best in class plywood, for fighting the damages caused by fire. Coatings, Inc. Product/Safety Data
Related Products View All Structural Solutions LP TechShield Learn More LP NovaCore Learn More LP WeatherLogic Learn More LP Legacy . Choose safety first with fire-fighting plywood and enjoy cooking with utmost peace of mind. - Firewall Technology emits less smoke protecting you from suffocation. American White Oak Veneer over Particle Board Construction. }
Inorganic materials like tile and brick also fall under the Class A category. FLAME RETARDANT & FIRE RESISTANT COATINGS, 1-888-990-3388
Typical Applications Applicable Standards Environment The total fire rating is determined by adding each component to reach a minimum total of 60 minutes. There are different kinds of fire-rated plywood, complete with different ratings. This makes it a safer type of wood to use in home structures and backboarding. View. You can usually find them on the tag where the details of the plywood are mentioned in the store. w/ 3/4" T&G plywood, ceiling 1/2" non -rated GWB: GFC101: Gypsum: Floor / Ceiling: 1-Hour: 2" x 10" @16" o.c., span 12'-14', live load 40lbs., w/ 3/4" wood sheathing . "telephone": "+1-415-459-6488",
Copyright Centuryply.com. LP FlameBlock Fire-Rated OSB Sheathing helps you meet fire codes while reducing dead load and wall thickness versus common alternatives. Standard precautions such as dust masks and goggles are sufficient when working with this type of wood because the chemicals used to give it fire-retardant properties are not considered hazardous. View our, New Products: USG Ceilings Inspirational Book, Danoline Acoustical Gypsum Inspirational Book, Acoustical Ceilings Performance Substrate, Ensemble Acoustical Drywall Ceiling Estimator, USG Acoustical Ceiling Panels & Acoustical Suspension Systems Catalog (WL294911), STRUCTO-CRETE Brand Structural Panels Portfolio, Levelrock & Durock Brand Fire & Sound Rating Guide, California Transparency in Supply Chain Act, Terms and Conditions for USG Sales/Terms and Conditions for USG POs. This test is used for more intricate estimates of fire protection. This makes it a safer type of wood to use in home structures and backboarding. Modern buildings are designed with safety in mind, and one of the biggest threats to many structures is fire. We offer a broad range of high-quality treated products that are suited to all types of projects. Forums. ICC-certified (ESR-1365) ATM manufactures grade A doors to the highest Standard as certified by SATAS ( SANS 545). For testing requirements, see Section 715.4.3. Quality is essential when seeking fire-rated plywood for building projects. This firewall technology allows a select range of CenturyPly plywood to be the most effective fire-fighting plywood available in India. //-->
Treated lumber is not fire-rated, nor should you try to treat it as if it is. USG STRUCTO-CRETE Brand Structural Panels. While time ratings vary, he says standard ratings include 20- to 90-minute doors. With that said, you dont have to stick to minimum standards to use fire-rated plywood. CLUB PRIME is made by a special pre-pressing technique that ensures equal distribution of moisture and adhesive. Fire safety experts agree its a great way to help make your home more fireproof. the rate of fire growth, total heat release, smoke production and burning droplets are measured by testing samples of the products to EN 13823 (The SBI test) and . USG provides resources here for our UL wall assemblies for seamless integration into any construction project. "url": "https://www.firefree.com",
Sometimes one product can meet multiple different levels of protection dependant on the substrate and how they are applied. "url": "https://www.firefree.com",
Wood that has been given a Class C rating has a flame spread number of 76 to 200. b. These properties of the fire retardant ply include: Lifetime Warranty For ArchitectPly / 30 years Warranty for ClubPrime. "++;i((iif){" +
a 30 minute fire door) and usually relates to a composite, an assembled product or a constructed setup. In order for wood to be considered fire-rated, it must have undergone a pressure treatment that infuses it with chemicals that give it fire-retardant properties. , w/1" x 8" wood planking , 2 layers 1/2" plywood, span 10', live load 40lbs, 2" x 8" F/D joists @16" o.c. The technology involves the use of nano engineered particles which are embedded in the polymer matrix of a plywood. One primary reason for spread of fire in houses or office space is furniture. Use the link below instead. 2023 USG Corporation. The panels are 4 feet wide, minimum 7/16-inch thick oriented strand board (OSB) or 15/32-inch thick structural sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PRP-108, and manufactured with exterior glue. Once the source of fire is removed it also acts to self-extinguish the fire. Fire security within our homes is more important than it ever has been and here at Leader Doors, we have a selection of FD30 . while (x = eval(x));
They are available in plain and horizontal slatted MDF, Plywood and in Solid Saligna. Fire-retardant Plywood substantially reduces this emission, thus preventing you from suffocation. In many cases, ordinary wood-frame construction with plywood or other wood structural panel sheathing provides ample fire safety and is completely acceptable. If you are unsure of whether a store has fire-rated plywood, the best thing you can do is call ahead to get the scoop.
The unique pressure treatment that fire-rated plywood is made with means that you should expect your plywood to stay fire-protective as long as it exists without fire. , w/5/8" plywood, span 8', live load 20lbs, 2" x 6" rafters @24" o.c.
X wood flooring, 1" x 3" wood spacers, embossed tin, 1-3/4" x 13-1/2" F/D @ 24"o.c., span 26', live load 40lbs, 3/4" T&G hardwood floor, 1" T&G pine ceiling, embossed tin. "contactPoint": [{
Items 1 - 738 of 743. }
LP FlameBlock is an ICC-approved component of 1- and 2-hour fire-rated wall assemblies and roof deck applications. If you are interested in giving your next construction project the benefits of fire-rated plywood, get in touch with the fire-retardant lumber professionals at Curtis Lumber & Plywood. The 24 means a maximum span of 24" on the roof and the 16 represents a maximum span of 16" on the floor. Quick buy. span 18', live load 60lbs, 2" x 6" T&G wood planking, 2-1/2" x 12" F/D @16" o.c., 1 layer 3/4" T&G pine, span 12'-6", live load 40 lbs, 2" x 12" F/D @ 16-18" o.c., span 11', live load 40lbs, 1-1/4" T&G Pine & 1-1/4" wood planks, 11-7/8" TJ'I's @ 16" o.c. span 35' w 4 x 14" purlons 8' o.c. There are 20 types of plywood, and not all of them are fire-rated. Firewall Technology helps one carry out the above by giving critical time to act and aid in rescue operations by curtailing the spread of fire and smoke generation. Currently the ArchitectPly and ClubPrime range available from April 2021 are coming with Firewall Technology. In addition to helping a building comply with applicable building codes, this material can also lower insurance costs. CenturyPly's fire- retardant plywood, delays the spread of fire, giving you the much-needed time to rescue yourself and your loved ones. With the second method, you may not get as much fireproofing. Unfortunately, like most other types of wood-based building materials, plywood burns. Reaction usually relates to individual material components, such as timber and plywood, where they are sold with a known and measured reaction to fire. When in doubt, ask a store associate whether or not the plywood you want to buy makes the grade. Span 23'-6" 3/4" T&G Wood, 1/4" lath w 3/4 " Plaster, ebossed tin, 2" x 14" @ 16" o.c., span 25", live load 40lbs, 2 layers 3/4" flooring, ceiling 3/4" T&G wood, embossed tin, 2" x 12" F/D oak wood @ 12" o.c., span 23', load 40lbs, 1 layer 3/4" wood plank, 1 layer 1 "plaster, 1 layer 3/4" t&g pine, support&frame 1" x 3" wood, tin, 2" x 10" @16" o.c., Span 14'-4", live load 40lbs, 1/4" wood lath, 1/2" plaster 1" wood spacers,embossed tin panels, 2-1/4" X 13-1/4" F/D @ 16" O.C., span 20, live load 40lbs, 3/4" hardwood or tile, 1" wood planking 1" x 3" wood spacers, embossed tin, 2" x 8" F/D @16" o.c., !"
Plywood is not a fire-rated product. Otherwise, you run the risk of having your home burn to the ground. "telephone": "+1-888-990-3388",
Firewall Technology is an indigenously developed, revolutionary technology that enables CenturyPly products to withstand the effect of fire far better than plywoods available in markets today.